Product Filter
  • Ionnic
Sold Out
Fully Insulated Blade Terminal Female BLU 4.8mm 16-14AWG 1.5-2.5mm2 Vinyl DC
Ionnic
MPN : QKC74
Fully Insulated Blade Terminal Female BLU 6.3mm 16-14AWG 1.5-2.5mm2 Heatshrink
Fully Insulated Blade Terminal Female BLU 6.3mm 16-14AWG 1.5-2.5mm2 Heatshrink
Ionnic
MPN : HDC35
$1.17
+GST
Fully Insulated Blade Terminal Female RED 6.3mm 22-16AWG 0.5-1.5mm2 Heatshrink
Fully Insulated Blade Terminal Female RED 6.3mm 22-16AWG 0.5-1.5mm2 Heatshrink
Ionnic
MPN : HDC16
$1.25
+GST
Fully Insulated Blade Terminal Female RED 6.3mm 22-16AWG 0.5-1.5mm2 Nylon DC - Connector-Tech ALS
Fully Insulated Blade Terminal Female RED 6.3mm 22-16AWG 0.5-1.5mm2 Nylon DC
Ionnic
MPN : QKC16
$0.25
+GST
Sold Out
Fully Insulated Blade Terminal Female RED 6.3mm 22-16AWG 0.5-1.5mm2 Vinyl DC
Ionnic
MPN : QKC73
Sold Out
Fully Insulated Blade Terminal Female YEL 4.8mm 14-10AWG 2.5-6mm2 Vinyl DC
Ionnic
MPN : QKC75
Fully Insulated Blade Terminal Female YEL 6.3mm 14-10AWG 2.5-6mm2 Heatshrink
Fully Insulated Blade Terminal Female YEL 6.3mm 14-10AWG 2.5-6mm2 Heatshrink
Ionnic
MPN : HDC55
$1.40
+GST
Fully Insulated Blade Terminal Male BLU 6.3mm 16-14AWG 1.5-2.5mm2 Heatshrink
Fully Insulated Blade Terminal Male BLU 6.3mm 16-14AWG 1.5-2.5mm2 Heatshrink
Ionnic
MPN : HDC65
$1.09
+GST
Fully Insulated Blade Terminal Male BLU 6.3mm 16-14AWG 1.5-2.5mm2 Nylon DC - Connector-Tech ALS
Fully Insulated Blade Terminal Male BLU 6.3mm 16-14AWG 1.5-2.5mm2 Nylon DC
Ionnic
MPN : NDC65
Fully Insulated Blade Terminal Male RED 6.3mm 22-16AWG 0.5-1.5mm2 Heatshrink
Fully Insulated Blade Terminal Male RED 6.3mm 22-16AWG 0.5-1.5mm2 Heatshrink
Ionnic
MPN : HDC64
$1.17
+GST
Fully Insulated Blade Terminal Male RED 6.3mm 22-16AWG 0.5-1.5mm2 Nylon DC - Connector-Tech ALS
Fully Insulated Blade Terminal Male RED 6.3mm 22-16AWG 0.5-1.5mm2 Nylon DC
Ionnic
MPN : NDC64
$0.25
+GST
Insulated Blade Terminal Male BLU 6.3mm 16-14AWG 1.5-2.5mm2 Heatshrink
Ionnic
MPN : HDC33
$1.17
+GST
Insulated Blade Terminal Male BLU 6.3mm 16-14AWG 1.5-2.5mm2 Vinyl DC
Ionnic
MPN : QKC33
Insulated Blade Terminal Male RED 2.8mm 22-16AWG 0.5-1.5mm2 Vinyl DC
Ionnic
MPN : QKC68
Insulated Blade Terminal Male RED 6.3mm 22-16AWG 0.5-1.5mm2 Heatshrink
Ionnic
MPN : HDC14
$1.17
+GST
Insulated Blade Terminal Male RED 6.3mm 22-16AWG 0.5-1.5mm2 Vinyl
Ionnic
MPN : QKC14
Insulated Blade Terminal Male YEL 2.8mm 14-10AWG 2.5-6mm2 Vinyl DC
Ionnic
MPN : QKC87
Insulated Blade Terminal Male YEL 6.3mm 14-10AWG 2.5-6mm2 Heatshrink
Insulated Blade Terminal Male YEL 6.3mm 14-10AWG 2.5-6mm2 Heatshrink
Ionnic
MPN : HDC87
$1.45
+GST
Insulated Flat Blade Terminal BLU 2.4x13mm 16-14AWG 1.5-2.5mm2 Vinyl DC
Ionnic
MPN : QKC71
$0.25
+GST
Insulated Flat Blade Terminal RED 2x10mm 22-16AWG 0.5-1.5mm2 Vinyl DC
Ionnic
MPN : QKC63
$0.22
+GST

When ordering a connector it is not always as simple matter of determining between 'male' and 'female' because this can refer to both the housing gender and the contact gender. Many manufacturers offer a given housing gender with both pin and socket. A common example of such confusion occurs in the Deutsch Industrial DT range, where the plug (or male connector) actually contains socket (or female) contacts. For this reason please specify both the contact and housing gender at the time of order.

The IP Rating of a connector or accessory relates to the degree of ingress protection provided by that component. The first digit of the code relates to the degree of protection against access to hazardous parts (conductors etc) and against solid foreign objects. The second digit refers to the degree of protection against the ingress of water. For two examples of this system, consider the most commonly seen IP ratings in our products: IP44 and IP67. IP44 4: Protection from solid objects ≤1mm | 4: Protection against splashing water IP67 6: Protection from dust-sized objects | 7: Protection against immersion in water at depth of 1m for 30mins A complete guide to all IP Ratings is available here.

These terms are used by Phase 3 and ITT Veam on their high-current connectors.The source is considered the half of the connection from which the power is sourced; or the half supplying the electrical power. In an emergency power application, the generator is the source and would be fitted with Panel Source (panel-mount) connectors, a Panel Source Powersafe Box, or Line Source (inline) connectors on pigtails. The drain is the half of the connection which drains the power from the source. In the same emergency power application described above, the network receiving the emergency power supply is the drain and would be fitted with Line Drain connectors, Panel Drain connectors or a Panel Drain Powersafe Box.

We commonly deal with both American Wire Gauge (AWG) and square millimetre (mm2) dimensions as the units used by manufacturers can vary. To convert between measurements please refer this conversion chart.